1.1 Specifications. Control Panel Specifications. Flexible Zone Configuration:. 8 Fully Programmable Zones. 38 Access Codes: 32 User, 1 System Master, 2 Partition Master, 2 Duress and 1 maintenance. Expandable to 32 Zones. Keypads with zone inputs available (PC/KP5508Z, PC/KP5516Z, PC/KP5532Z, LCD/KPL5500Z). Hardwired expansion available using the PC5108 Eight Zone Expansion Module. Title: PC5010 Programming Worksheets Author: Technical Manuals Online! Subject: Created Date: 10:48:39 AM. Keypads connected to the PC5010 panel can be assigned one of three ways: a keypad can be assigned to operate partition 1, partition 2 or as a global keypad. Global keypads will not display any information (except for a trouble condition, if present) until the keypad is temporarily assigned.
Expandable and Flexible
This item: DSC PowerSeries PK5500 Alarm Keypad $138.98. Ships from and sold by JMAC Supply. Digital Security Controls PC1832NK 8 ZONE HYBRID CONTROL PANEL EXP TO 32 ZONES LARGE CABINET $118.41. Ships from and sold by ISS Inc. ELK TRG1640 AC Transformer 16.5VAC, 45. How to unlock the DSC alarm PC-5010 If you h.
The DSC Power 832, also known as Model PC5010 has been one of the most popular DSC security products for years. It is inexpensive, feature-packed, and versatile, which has made it a popular choice for DIY alarm systems.
It’s also the system I chose for my own home, and I’ll tell you why in a minute.
The Power 832 has been discontinued, although they are still available through some outlets. Existing 832 home security systems in good condition will also be in operation for years to come.
If you have one in your home now, or if you 'inherit' one in the future, this page will help you get acquainted with the system.
You may also want to check out these pages:
You can find links to free DSC manuals on my alarm system manual sources page.
If you’re planning a new installation, read on. You’ll see why this DSC panel is so popular, and how its replacement may be the system you’re looking for!
The DSC 832 can use several alarm keypads. LED (Light Emitting Diode) keypad models include:
- PC5508(Z) 8-LED zone lights
- PC5516(Z) 16-LED zone lights
- PC5532(Z) 32-LED zone lights
The LCD (Liquid Crystal Display) keypad is the model LCD5500(Z), and uses alphanumeric text and numbers to display information. All keypads operate in virtually the same way.
The 832 system can support up to a total of 8 keypads in any combination.
DSC Power 832 Basic Features
The basic DSC 832 panel has 8 on-board zones for burglary devices, plus a dedicated fire zone via the PGM terminals.
The burglary zones are individually programmable for many different responses, so zones can be customized to match many applications. Burglar zones can be added using up to (3) 5108 zone expander modules, each of which adds 8 zones to the basic system. This gives the PC 5010 a maximum capacity of 32 burglary zones, hardwired or wireless.
The fire zone is optimized for 2-wire smoke detectors using the PGM2 terminal. The connections are compatible with several different 2-wire smoke alarm models, and provide both switched power and alarm functions on the same two terminals.
Using one of the two PGM Outputs allows the DSC 832 to work with 4-wire smoke detectors. The PGM out provides switched power for resetting the 4-wire smokes, while one of the standard zone inputs is programmed for the fire alarm function.
The two PGM outputs can be programmed for many other functions, including relay activation, system status outputs, etc.
Status outputs like system trouble and armed condition are automatically issued by the panel.
The user can initiate relay outputs through button presses at a system keypad. In addition, relays can be activated remotely with the addition of an Escort module (see below).
Why Did I Choose the DSC Power 832?
At the time I installed a DSC Power 832 in my own home, I had my choice of any panel on the market. After many years in the alarm business, I had seen many panels come and go, while others remained popular.
My first requirement was for a system that is keypad programmable. This rules out most of the Radionics line, which require a separate handheld programmer.
Secondly, I wanted Alpha display keypads with customizable text. These were available with several brands of alarm, including Ademco home security systems, and I wouldn’t have gone wrong choosing one of them.
My third major requirement was the easiest to get, since it’s virtually the standard in the industry: Zone expandability. The 4-bedroom, 2-bath house my wife and I live in has four doors and about a dozen movable windows. I wanted each opening on its own zone, which the DSC 832 can support by adding a single 8-zone expansion module.
Finally, I had recently helped a customer learn to operate their DSC 832 system with the Escort 5580TC module installed. This device connects to the Power 832 alarm, and gives you remote access to your system via telephone.
I’m a “gadget guy”, and I liked the idea of being able to call my home, check the status of the system, arm and disarm it, etc.
In the end, I settled on the DSC Power 832, adding a zone expander and an Escort module. I programmed the system for remote access, and connected the panel to control my garage overhead door. Now, I never have to wonder if I forgot to close the garage door; I can just call the panel from anywhere, check the door’s status, and press a few buttons to close it.
The DSC Power 832 security system has given us flawless service for over 15 years. The only work I’ve done on it is a routine battery change every couple of years or so.
The Next Generation:
The DSC Power 1832
If you’re planning a new DIY alarm system, or are having one professionally installed, you may want to consider the DSC Power 1832. It can readily fill the niche left by the discontinued Power 832, and the programming and operation are very similar.
The DSC Power 1832 does everything the 832 could do, along with having 4 partitions (the 832 only has 2 partitions) and other new features.
See pricing and features of the DSC 1832 security system at Amazon.com.
Conclusion
If you find yourself the new owner of a previously installed DSC Power 832 system in good condition, consider yourself lucky. If it has the features you want in an alarm system, it will likely serve you well for years to come.
If your system is not in the best condition, here are some things to think about:
- If you don't know the installer code and have a programming manual, you won't be able to program the higher functions of the panel, like the zone types, dialer, account information, etc.
- Most newer DSC keypads are backwards-compatible with older models of panel, so you can probably find a replacement for a worn-out keypad. Depending on the age and condition of your Power 832 system, this could be a good option
- A new system can easily be had these days for as little as $99, or even free in some cases, provided you go with monitoring. This makes spending money on a very old or worn-out system much less cost effective than it used to be
- If you own a smartphone or other web-enabled device, consider how handy it would be to use it to remotely arm and disarm your system. Many newer systems are designed to be smartphone-compatible from the ground up. If you happen to have (or plan to have) cameras, many systems allow remote live viewing and playback on smart devices
A new system purchased through a home alarm company will likely include the security equipment they like and are most familiar with. With its flexibility and features, don’t be surprised if they recommend a DSC system!
Related Articles:
DSC 832 Tips and Advice for Older Systems
DSC Power 1832
Do you have an older system that's starting to have problems?
Or, do you have a working system, but no programming information?
Why not get a few Free Home Security Systems Quotes from companies in your area?
Return to Home-Security-Systems-Answers from DSC Power 832
Return to DSC Security Systems from DSC Power 832
Note: Feel free to print any of the articles on this site for personal, non-commercial use. Just look for this button:
Causes and Solutions
If your DSC home alarm is beeping every 10 seconds or so, there could be many possible causes. In most cases, it’s because the alarm panel has detected one or more “trouble” conditions. These include things like low battery trouble, phone line failure, and communication problems, among many others.
Note: DSC keypads also emit 'normal' beeping caused by the 'Chime' function. You can easily toggle this on or off by pressing and holding the 'Chime' button on any keypad that has function keys. For keypads without a chime button, just press '*4'.
On this page, I’ll show you how to silence trouble beeping, and how to use a few easy keypad commands to find the source of the trouble. I’ll also explain how to fix some of the most common causes of alarm system beeping.
If you have a brand of alarm panel other than DSC, see 'My Alarm Keeps Beeping - What Can I Do?'.
While beeping alarm keypads can be very annoying, they’re designed that way for a reason. The alarm beep is intended to get your attention so you’ll go to the keypad, where you can then get a detailed visual indication of what the problem is. Unfortunately, these problems usually seem to crop up in the middle of the night!
How to Silence the Beeping Keypads
1) Go to any keypad and make sure the system is disarmed. If not, enter your disarm code as usual.
2) Press the “#” key. This will silence your DSC alarm system keypads.
With the noise eliminated, you can relax a bit and figure out what to do next.
Be aware that the keypads COULD begin beeping again.
The # key doesn’t DISABLE beeping keypads; it only stops beeps for the CURRENT trouble condition.
Keypads may begin beeping again if:
1. The ORIGINAL cause of the trouble condition momentarily clears itself, then returns, or
2. A DIFFERENT trouble condition occurs
In either case, pressing the # key again will acknowledge and silence the latest beeping event.
Reading Trouble Conditions
Trouble codes are displayed on DSC keypads using either LED’s (on basic LED keypads) or as text (on LCD keypads with alphanumeric displays).
Over the years, DSC has made many different alarm panels, and they don’t all share the same trouble code scheme. For this reason, I highly recommend you download a copy of the “User Manual” for your specific panel model.
You can find links to free DSC manuals on my alarm system manual sources page.
Displaying the Trouble Codes
Go to any keypad and press “*”, then “2”. The keypad will switch from its “idle” display to its “trouble code” display. The lit LED’s or text will now correspond to the trouble code table. The example below is for the Power 832/864 family of panels.
Notice that if a “1” is displayed (“Service Required”), pressing the “1” key again will cause the specific problem to be displayed.
Note: If you have a DSC model PC4020, there won’t be any numbers. This system uses LCD keypads with fixed displays, so instead of numbers, the trouble condition is spelled out in text form.
Make a note of the trouble condition(s). I’ve listed some of the most common problems below, along with ways to handle them.
After attempting to correct any of the problems below, the trouble display may not clear immediately. Arming, then disarming the system will reset most trouble displays.
If there are no trouble codes displayed when you press *2, your DSC system isn’t the problem.
The beeping is probably coming from another device. For example, you may have a hard wired smoke detector chirping due to a low battery.
In that case, see How to Stop a Beeping Smoke Alarm.
Top 6 Reasons Why Your DSC Home Alarm is Beeping
1. Battery Trouble
If your DSC home alarm is beeping due to this condition, the main panel battery is low or failing.
If you’ve recently had a power outage, wait 24-48 hours after power is restored. The battery may simply have discharged, and will recharge when the electricity comes back on. If the beeping persists, the battery probably needs to be replaced.
The battery can be replaced by your alarm company, if you have one. Or, if you’re fairly handy, you may be able to fix it yourself. Replacing an alarm battery isn’t very difficult, provided you can reach the main panel box.
For details on doing this yourself, see my page on DIY alarm system battery replacement.
2. AC Trouble
If your DSC home alarm is beeping for AC trouble, it means that the panel isn’t getting power from the low voltage transformer. This is a small cube that plugs into an outlet, usually near the main panel.
Possible problems and solutions:
- Transformer is unplugged (Plug it in)
- Transformer has a blown internal fuse (Replace transformer)
- Outlet has no power (Check for a tripped circuit breaker)
For transformer details, see the alarm system battery page.
3. TLM Trouble – Telephone Line Monitor
If your DSC home alarm is beeping due to this condition, then it isn’t able to see the telephone line. The line may have been cut or damaged, or the phone service may simply be down.
If your phones are out, check for dial tone by plugging a standard telephone into the jack in the phone box outside the house.
If it’s dead there, call your phone service provider.
If it’s good, something may have been disconnected between the alarm panel and the exterior phone box. In this case, you’ll probably need an alarm technician to come out and trace the line.
4. FTC Trouble – Fail to Communicate
When a DSC home alarm is beeping for this condition, it means that the panel was unable to call the central station. This could be a result of no phone line as described above, in which case fixing the line will clear this condition as well.
Otherwise, check with your alarm company for instructions. They can check your alarm’s reporting activity, and advise you on further steps to take.
Note: FTC troubles will clear only when the panel successfully sends a signal to the central station. Call your alarm representative for help with this.
5. Zone Tamper and Low Zone Battery Trouble
If your DSC home alarm is beeping for either of these conditions, there is a problem with some form of wireless security equipment. This can include wireless door and window transmitters, remote keypads, and wireless keyfobs.
Tamper means the plastic cover is loose, missing, or somehow not attached correctly. Check the affected zone; you may be able to easily re-attach a loose cover.
A Low Zone Battery is generated when a remote transmitter battery is low or failing. If you do your own battery changes, replace the batteries in the affected transmitters. Otherwise, contact your alarm company for service.
6. Loss of System Time
If your DSC home alarm is beeping for time loss, the internal clock will need to be reset. To do this, follow these steps:
- Press (*6) (Master Code) (1)
- Enter the time as HH MM in 24-hour format (00:00 to 23:59)
- Enter the date as MM DD YY
All entries must be 2-digits; for example, January is month 01.
These are the system trouble conditions I’ve seen most often. For help with other trouble conditions, check the manual for your specific panel model.
If your DSC home alarm is beeping even after you’ve tried everything, it may be time to consider replacing it.
This is especially true if you have an older system that's been discontinued.
Some points to consider:
- Most newer DSC keypads are backwards-compatible with older models of panel, so you can probably find a replacement for a worn-out keypad. Depending on the age and condition of the system, this could be a good option
- A new system can easily be had these days for as little as $99, or even free in some cases, provided you go with monitoring. This makes spending money on a very old system much less cost effective than it used to be
- If you own a smartphone or other web-enabled device, consider how handy it would be to use it to remotely arm and disarm your system. Many newer systems are designed to be smartphone-compatible from the ground up. If you happen to have (or plan to have) cameras, many systems allow remote live viewing and playback on smart devices
If you need to replace a hardwired DSC system, there is some good news...
You already have wiring in place, which is often the biggest expense for a hardwired system.
And, you can probably re-use your existing hardwired devices like door and window contacts, motion detectors, and glassbreak detectors with the new system.
If you have an older system that's starting to have problems, you may be thinking about replacing it.
To find out how much a new system might cost, get some free price quotes from alarm dealers in your area. Just answer a few questions below, and you'll receive your quotes via email.
These quotes are absolutely free!
Dsc Power 832 Pc5010 Keypad
Related Articles:
DSC 832 Tips and Advice
DSC Power 832
The DSC Power 1832 - Doing the DSC 832 'One' Better!
Dsc Pc5010 User Manual
Help with other brands:
Radionics Alarm Systems
Return to DSC Security Systems from DSC Home Alarm is Beeping
Return to Home Security Systems Answers from DSC Home Alarm is Beeping
Note: Feel free to print any of the articles on this site for personal, non-commercial use. Just look for this button: